Note 29 |
In addition to Device Types, which are required for all offices regardless of the type of Cable Pressurization Automatic Monitoring System (CPAMS) used, PressureMAP systems that monitor 289, 289H LSS, 289H-M and Dial-a-Ducers also require that a Transducer Type code is assigned to each device. This code provides additional information required by PressureMAP to perform 289-related monitoring functions. For some Device Types, the PressureMAP editor automatically fills in the required TD Type, and will not allow you to edit that field.
Device Types and Transducer Types are listed in Appendix 1 of the MAP System Data Entry Manual and at the end of the Preface in the Operations Manual.
289 AND 289H RESISTIVE TRANSDUCER TYPES
PressurePSI
RP |
Standard Resistive Pressure Transducer: 0-9.5 PSI |
RP/HP-PSI |
High Pressure Resistive Transducer: 5-14.5 PSI |
RP/RG-PSI |
High Pressure Resistive Transducer: 5-14.5 PSI |
RP/RG/HP-PSI |
Resistive Pressure Transducer using ring with sheath as ground |
RP/TG-PSI |
High Pressure Resistive Transducer using ring with sheath as ground |
RP/TG/HP-PSI |
High Pressure Resistive Transducer using tip with sheath as ground |
PressureKPA
RP-KPA |
Standard Resistive KPA Pressure Transducer: 0-65.5 KPA |
RP/HP-KPA | High Pressure Resistive KPA Transducer: 34.48-99.98 KPA |
RP/RG-KPA | Resistive KPA Pressure Transducer using ring with sheath as ground |
RP/RG/HP-KPA | Resistive KPA Pressure Transducer using ring with sheath as ground |
RP/TG-KPA | Resistive KPA Pressure Transducer using tip with sheath as ground |
RP/TG/HP-KPA | High Pressure Resistive KPA Transducer using tip with sheath as ground |
FlowSCFH
RF/(range) |
Standard Resistive Flow Transducer-9 ranges of SCFH: 0-9.5, 0-19.0, 0-20.0, 0-47.5, 0-50.0, 0-95.0, 0-100.0, 0-185.0, 0-200.0 |
RF/RG/(range) |
Resistive Flow Transducer using ring with sheath as ground-9 ranges of SCFH: 0-9.5, 0-19.0, 0-20.0, 0-47.5, 0-50.0, 0-95.0, 0-100.0, 0-185.0, 0-200.0 |
RF/TG/(range) |
Resistive Flow Transducer using tip with sheath as ground-9 ranges of SCFH: 0-9.5, 0-19.0, 0-20.0, 0-47.5, 0-50.0, 0-95.0, 0-100.0, 0-185.0, 0-200.0 |
FlowLPH
RF/(range) |
Resistive Flow Transducer-9 ranges of LPH: 0-270, 0-540, 0-570, 0-1350, 0-1420, 0-2700, 0-2830, 0-5380, 0-5670 |
RF/RG/(range) |
Resistive Flow Transducer using ring with sheath as ground-9 ranges of LPH: 0-270, 0-540, 0-570, 0-1350, 0-1420, 0-2700, 0-2830, 0-5380, 0-5670 |
RF/TG/(range) |
Resistive Flow Transducer using tip with sheath as ground-9 ranges of LPH: 0-270, 0-540, 0-570, 0-1350, 0-1420, 0-2700, 0-2830, 0-5380, 0-5670 |
Contact Alarm
CPAMS_TD |
Standard Resistive Contact Alarm |
CPAMS_TD/RG |
Resistive Contact Alarm using ring with sheath as ground |
CPAMS_TD/TG |
Resistive Contact Alarm using tip with sheath as ground |
AC/115 |
Contact Alarm for 115V: 540K resistance OK, 270K resistance is ALRM |
DRYER |
Contact Alarm for 115V: 540K resistance OK, 270K resistance is ALRM (same as AC/115) |
AC/230 |
Contact Alarm for 230V; 540K resistance OK, 270K resistance is ALRM |
RR/540K |
Contact Alarm; 540K resistance OK, SHRT is ALRM |
Other Device Applications
RG/100M |
Resistive open pair, monitors the resistance of a pair (Ring/Ground) |
RR/100M |
Resistive open pair, monitors the resistance of a pair (Tip/Ring) |
RT/100M |
Resistive open pair, monitors the resistance of a pair (Tip/Ground) |
TEMP/212 |
Thermistor Water Temperature Transducer; range -40 to +212o |
TEMP/212/H |
Thermistor Air Temperature Transducer; range 32 to 212o |
289 AND 289H CURRENT LOOP TRANSDUCER TYPES
PressurePSI
CPA/15.0 |
Current Loop Pressure Transducer, 0-15.0 PSI (absolute) |
CPA/30.0 |
Current Loop Pressure Transducer, 0-30.0 PSI (absolute) |
PressureKPA
CPA/100.0 |
Current Loop Pressure Transducer, 0-100.0 KPA (absolute) |
CPA/200.0 |
Current Loop Pressure Transducer, 0-200.0 KPA (absolute) |
FlowSCFH
CF/9.5 |
Current Loop Flow Transducer, 0-9.5 SCFH |
CF/19.0 |
Current Loop Flow Transducer, 0-19.0 SCFH |
CF/47.5 |
Current Loop Flow Transducer, 0-47.5 SCFH |
CF/95.0 |
Current Loop Flow Transducer, 0-95.0 SCFH |
CF/475.0 |
Current Loop Flow Transducer, 0-475 SCFH |
CF/950.0 |
Current Loop Flow Transducer, 0-950 SCFH |
FlowLPH
CF/270 |
Current Loop Flow Transducer, 0-270 LPH |
CF/540 |
Current Loop Flow Transducer, 0-540 LPH |
CF/1350 |
Current Loop Flow Transducer, 0-1350 LPH |
CF/2700 |
Current Loop Flow Transducer, 0-2700 LPH |
CF/13500 |
Current Loop Flow Transducer, 0-13500 LPH |
CF/27000 |
Current Loop Flow Transducer, 0-27000 LPH |
Other Device Applications
BARO/35 |
Bi-Directional Flow Transducer, range 0-475 SCFH |
BARO/1200 |
Barometric Pressure Transducer, range 750-1200 millibars |
BFTD/475.0 |
Barometric Pressure Transducer, range 20.6-91.1 inches of Hg |
RH/100 |
Relative Humidity Transducer, range 0%-100% RH |
TANK |
Tank Volume Transducer, 0-200 cubic ft |
EURO_TANK |
Tank Pressure Transducer (metric), 0-204 bars |
TEMP/167 |
Temperature Transducer, range 0-167o F |
TEMP/75 |
Temperature Transducer, range 0-75o C |
WATER/20 |
Water Level Transducer, range 0-20.8 inches |
WATER/30 |
Water Level Transducer, range 0-30 feet |
289H Voltage Measurement Transducer Types
VAC/TG |
AC Voltage, Tip to Ground |
VAC/RG |
AC Voltage, Ring to Ground |
VDC/TG |
DC Voltage, Tip to Ground |
VDC/RG |
DC Voltage, Ring to Ground |
VAC/300 |
AC Voltage, Tip to Ring |
289H LSS ADDRESSABLE TRANSDUCER TYPES
FlowSCFH
AF/9.5 |
289H Addressable Flow Transducer, 0-9.5 SCFH |
AF/19.0 |
289H Addressable Flow Transducer, 0-19.0 SCFH |
AF/47.5 |
289H Addressable Flow Transducer, 0-47.5 SCFH |
AF/95.0 |
289H Addressable Flow Transducer, 0-95.0 SCFH |
AF/475.0 |
289H Addressable Flow Transducer, 0-475.0 SCFH |
AF/950.0 |
289H Addressable Flow Transducer, 0-950.0 SCFH |
FlowLPH
AF/270 |
289H Addressable Flow Transducer, 0-270 LPH |
AF/540 |
289H Addressable Flow Transducer, 0-540 LPH |
AF/1350 |
289H Addressable Flow Transducer, 0-1350 LPH |
AF/2700 |
289H Addressable Flow Transducer, 0-2700 LPH |
PressurePSI
APA |
289H Addressable PSI Pressure Transducer, 0-15 PSI (absolute) |
PressureKPA
APA/KPA |
289H Addressable Pressure Transducer, 0-100.0 KPA (absolute) |
DualPressure Side
APA/X2 |
289H Addressable Pressure/Flow Transducer, 0-15.0 PSI (absolute) |
APA/KPAX2 |
289H Addressable Pressure/Flow Transducer, 0-100.0 KPA (absolute) |
DualFlow Side
AF/9.5X2 |
289H Addressable Pressure/Flow Transducer, 0-9.5 SCFH |
AF/19.0X2 |
289H Addressable Pressure/Flow Transducer, 0-19.0 SCFH |
AF/47.5X2 |
289H Addressable Pressure/Flow Transducer, 0-47.5 SCFH |
AF/95.0X2 |
289H Addressable Pressure/Flow Transducer, 0-95.0 SCFH |
AF/475.0X2 |
289H Addressable Pressure/Flow Transducer, 0-475.0 SCFH |
AF/950.0X2 |
289H Addressable Pressure/Flow Transducer, 0-950.0 SCFH |
AF/270X2 |
289H Addressable Pressure/Flow Transducer, 0-270 LPH |
AF/540X2 |
289H Addressable Pressure/Flow Transducer, 0-540 LPH |
AF/1350X2 |
289H Addressable Pressure/Flow Transducer, 0-1350 LPH |
AF/2700X2 |
89H Addressable Pressure/Flow Transducer, 0-2700 LPH |
Special Addressable Transducers
ABARO/1200 |
289H Addressable Barometric Pressure Transducer, 750-1200 millibars |
ABARO/35 |
289H Addressable Barometric Pressure Transducer, 20.6-35.0 inches of Hg |
AWATER/30 |
289H Addressable Water Level Transducer, 0-30 feet |
CHATLOS ADDRESSABLE TRANSDUCER TYPES
FlowSCFH
AF/C9.5 |
Chatlos Addressable Flow Transducer, 0-9.5 SCFH |
AF/C5/9.5 |
Chatlos 5-Bank Addressable Flow Transducer, 0-9.5 SCFH |
AF/C10/9.5 |
Chatlos 10-Bank Addressable Flow Transducer, 0-9.5 SCFH |
AF/C19.0 |
Chatlos Addressable Flow Transducer, 0-19.0 SCFH |
AF/C5/19.0 |
Chatlos 5-Bank Addressable Flow Transducer, 0-19.0 SCFH |
AF/C10/19.0 |
Chatlos 10-Bank Addressable Flow Transducer, 0-19.0 SCFH |
AF/C47.5 |
Chatlos Addressable Flow Transducer, 0-47.5 SCFH |
AF/C5/47.5 |
Chatlos 5-Bank Addressable Flow Transducer, 0-47.5 SCFH |
AF/C10/47.5 |
Chatlos 10-Bank Addressable Flow Transducer, 0-47.5 SCFH |
AF/C50.0 |
Chatlos Addressable Flow Transducer, 0-50.0 SCFH |
AF/C5/50.0 |
Chatlos 5-Bank Addressable Flow Transducer, 0-50.0 SCFH |
AF/C10/50.0 |
Chatlos 10-Bank Addressable Flow Transducer, 0-50.0 SCFH |
AF/C95.0 |
Chatlos Addressable Flow Transducer, 0-95.0 SCFH |
AF/C5/95.0 |
Chatlos 5-Bank Addressable Flow Transducer, 0-95.0 SCFH |
AF/C10/95.0 |
Chatlos 10-Bank Addressable Flow Transducer, 0-95.0 SCFH |
AF/C100.0 |
Chatlos Addressable Flow Transducer, 0-100.0 SCFH |
AF/C5/100.0 |
Chatlos 5-Bank Addressable Flow Transducer, 0-100.0 SCFH |
AF/C10/100.0 |
Chatlos 10-Bank Addressable Flow Transducer, 0-100.0 SCFH |
FlowLPH
AF/C270 |
Chatlos Addressable Flow Transducer, 0-270 LPH |
AF/C5/270 | Chatlos 5-Bank Addressable Flow Transducer, 0-270 LPH |
AF/C10/270 |
Chatlos 10-Bank Addressable Flow Transducer, 0-270 LPH |
AF/C540 | Chatlos Addressable Flow Transducer, 0-540 LPH |
AF/C5/540 | Chatlos 5-Bank Addressable Flow Transducer, 0-540 LPH |
AF/C10/540 | Chatlos 10-Bank Addressable Flow Transducer, 0-540 LPH |
AF/C1350 | Chatlos Addressable Flow Transducer, 0-1350 LPH |
AF/C5/1350 | Chatlos 5-Bank Addressable Flow Transducer, 0-1350 LPH |
AF/C10/1350 | Chatlos 10-Bank Addressable Flow Transducer, 0-1350 LPH |
AF/C1420 | Chatlos Addressable Flow Transducer 0-1420 LPH |
AF/C5/1420 | Chatlos 5-Bank Addressable Flow Transducer 0-1420 LPH |
AF/C10/1420 | Chatlos 10-Bank Addressable Flow Transducer 0-1420 LPH |
AF/C2700 | Chatlos Addressable Flow Transducer, 0-2700 LPH |
AF/C5/2700 | Chatlos 5-Bank Addressable Flow Transducer, 0-2700 LPH |
AF/C10/2700 | Chatlos 10-Bank Addressable Flow Transducer, 0-2700 LPH |
AF/C2830 | Chatlos Addressable Flow Transducer, 0-2830 LPH |
AF/C5/2830 | Chatlos 5-Bank Addressable Flow Transducer, 0-2830 LPH |
AF/C10/2830 | Chatlos 10-Bank Addressable Flow Transducer, 0-2830 LPH |
PressurePSI
AP/C |
Chatlos Addressable PSI Pressure Transducer |
AP/C5 |
Chatlos 5-Bank Addressable PSI Pressure Transducer |
AP/C10 |
Chatlos 10-Bank Addressable PSI Pressure Transducer |
AP/CH-PSI |
Chatlos Addressable PSI High Pressure Transducer |
AP/C5/H-PSI |
Chatlos 5/10-Bank Addressable PSI High Pressure Transducer |
PressureKPA
AP/C-KPA |
Chatlos Addressable KPA Pressure Transducer |
AP/C5/KPA |
Chatlos 5/10-Bank Addressable KPA Pressure Transducer |
AP/CH-KPA |
Chatlos Addressable KPA High Pressure Transducer |
AP/C5/H-KPA |
Chatlos 5/10-Bank Addressable KPA High Pressure Transducer |
UAMC ADDRESSABLE TRANSDUCER TYPES
Pressure
AP/I |
Inelcom Addressable mbar Pressure Transducer |
AP/L |
Lancier Addressable mbar Pressure Transducer |
AP/M |
Microsol Addressable mbar Pressure Transducer |
AP/N |
Nicotra Addressable mbar Pressure Transducer |
AP/S730 |
Sparton Addressable mbar Pressure Transducer, 0-10 PSI |
AP/S734 |
Sparton Addressable mbar Pressure Transducer, 0-14.5 PSI |
Flow
AF/S9.5 |
Sparton Addressable SCFH Flow Transducer, 0-9.5 SCFH |
AF/S20 |
Sparton Addressable SCFH Flow Transducer, 0-20 SCFH |
AF/S50 |
Sparton Addressable SCFH Flow Transducer, 0-50 SCFH |
AF/S100 |
Sparton Addressable SCFH Flow Transducer, 0-100 SCFH |
DIAL-A-DUCER TRANSDUCER TYPES
FlowSCFH
DF/9.5 |
Flow Transducer, 0-9.5 SCFH |
DF/19.0 |
Flow Transducer, 0-19.0 SCFH |
DF/47.5 |
Flow Transducer, 0-47.5 SCFH |
DF/95.0 |
Flow Transducer, 0-95.0 SCFH |
DF/475.0 |
Flow Transducer, 0-475.0 SCFH |
DF/950.0 |
Flow Transducer, 0-950.0 SCFH |
FlowLPH
DF/270 |
Flow Transducer, 0-270 LPH |
DF/540 |
Flow Transducer, 0-540 LPH |
DF/1350 |
Flow Transducer, 0-1350 LPH |
DF/2700 |
Flow Transducer, 0-2700 LPH |
DF/13500 |
Flow Transducer, 0-13500 LPH |
DF/27000 |
Flow Transducer, 0-27000 LPH |
PressurePSI
DP/15.0 |
Pressure Transducer, gauge type |
PressureKPA
DP/100.0 |
Pressure Transducer, gauge type |
Other Device Applications
DT/167 |
Fahrenheit Temperature Transducer, (FT device type) |
DI | Digital Input (CA device type); support the following values: |
For additional information regarding Transducer Type coding, call System Studies at (800) 247-8255 or (831) 475-5777, or email your request to Technical Support.
If you are interested in learning more about System Studies products, please contact us. We are ready to assist you in gaining a much tighter control of your valuable outside plant investment.
© 1996-2008 System Studies Inc. All rights reserved.
(800) 247-8255 | (831) 475-5777