home button icon
 
Heading Text: Office Equipment, Field Hardware
Bracket Assemblies


Manifold Monitoring Assembly
Manifold Assembly To provide ease and convenience for monitored manifold installations, System Studies provides a bracket assembly with either one or two Flow Finder Manifolds™ pneumatically connected to a High Resolution Flow or High Resolution Dual (pressure/flow) Transducer. The pneumatic connections between the transducer and the manifold(s) are accomplished by the use of two 1/8 inch (0.3 cm) stainless steel rigid tubes. These tubes are standard on all models.

Please note that there are numerous ordering options for the Manifold Monitoring Assembly™. The variations are defined in the last eight characters of the model number (3061-MBS-1, for example). The first group of four digits identifies the type of conductor tube fitting supplied on the assembly's transducer. Model 3061 includes a 1/8 inch (0.3 cm) NPT to 3/8 inch (1 cm) plastic tube fitting; model 3064 is supplied with a 37° flared, stainless steel fitting.

The next group of three letters pertain to the Flow Finder™ ranges and the type of connector fittings/accessories supplied on the manifold's outgoing ports. The final designation identifies the transducer supplied ("1" for flow and "2" for dual) and whether the transducer is equipped with a pair saver ("P"). This internally installed device makes it possible to connect a dual transducer to a single conductor pair.


Ordering Information

 PART NUMBER  RANGE*  FITTINGS**  TD TYPE***
9800-3061  ONE MANIFOLD
(transducer has 3/8" nickel-plated brass conductor tube fitting)
L, M, H, C BS, BT, BV 1, 2, 9, U, U2, 2P
9800-3064  ONE MANIFOLD
(transducer has 37° stainless steel conductor tube fitting)
L, M, H, C SS, SV 1, 2, 9, 2P
9800-3062  TWO MANIFOLDS
(transducer has nickel-plated brass conductor tube fitting)
L, M, H, C BS, BT, BV 1, 2, 9, U, U2, 2P
9800-3065  TWO MANIFOLDS
(transducer has 37° stainless steel conductor tube fitting)
L, M, H, C SS, SV 1, 2, 9, 2P
9802-3062  TWO MANIFOLDS
(manifolds and transducer installed on curved bracket, transducer has nickel-plated brass conductor tube fitting)
M, H BS, BV 1, 2, U

*Range:
L Low: Input = 19.0 SCFH, Output = 9.5 SCFH
M Medium: Input = 47.5 SCFH, Output = 9.5 SCFH
H High: Input = 95 SCFH, Output = 195 SCFH
C Custom: Multiple output ranges to meet customer specifications (contact System Studies Incorporated)

**Fittings:
BS Manifold(s) supplied with nickel-plated brass, standard tubing connectors. For use with 3/8" plastic tubing.
BT Manifold(s) supplied with nickel-plated brass, standard tubing connectors. For use with 1/4" plastic tubing.
BV Manifold(s) supplied with nickel-plated brass, standard tubing connectors, along with nickel-plated brass check valves on all outputs. For use with 3/8" plastic tubing.
SS Manifold(s) supplied with stainless steel 37° flared tubing connectors. For use with 1/4" stainless steel braided tubing.
SV Manifold(s) supplied with stainless steel 37° flared tubing connectors, along with nickel-plated brass check valves on all outputs. For use with 1/4" stainless steel braided tubing.

***Transducer Type:
1 High Resolution Flow Transducer 2 High Resolution Dual (pressure/flow) Transducer
9 No Transducer Supplied U Resistive Flow Transducer
2P High Resolution Dual Transducer (w/Selector Pair Saver) U2 Resistive Flow & Pressure Transducer
 
Please note that an eight digit part number, range, fitting and transducer type designation must be specified for each Manifold Monitoring Assembly when ordering.

Ordering Examples:
If you ordered part number 9800-3064-HSV-2, you would receive an assembly consisting of a Flow Finder Manifold with a high flow range (95.0 SSCFH input and 19.0 SCFH outputs), 37° stainless steel flared tubing connectors with nickel-plated brass check valves, and a High Resolution Dual Transducer with a 37° stainless steel conductor fitting.

Model number 9802-3062-MBS-2, shown below, is a curved Manifold Monitoring Assembly with medium range Flow Finders (47.5 SCFH input and 9.5 SCFH outputs). It also includes a High Resolution Dual Transducer with a standard nickel-plated brass conductor tube fitting for 3/8" plastic tubing. This model is designed to be installed in the circular collar of a manhole.

Curved Manifold Assembly

For additional information about our Manifold Monitoring Assemblies, please refer to the product data sheet. Pricing information can be obtained from your Purchasing Department or by calling System Studies Incorporated at 800-247-8255.